Site Map:
FHRA_Watercourse_Summary_Map_June_2025.pdf
SECTION 1: OE2 - OE1
https://fhra-media.s3.eu-west-1.amazonaws.com/OE2-OE1.mp4
- Issue:
- Coarse settled deposits caused 40% cross-sectional area loss at 0.24m.
- Survey abandoned at 0.50m due to debris blocking the camera.
- Likely Cause: Poor fall or sedimentation in low-flow pipe.
- Chalet Number: FHRA land
SECTION 2: SW1-OE1
https://fhra-media.s3.eu-west-1.amazonaws.com/SW1-OE1.mp4
- Issue:
- Multiple structural and service defects:
- Root ingress at joints (fine and tap) from 23.38m–27.52m.
- Defective intruding connection at 11.62m (100mm pipe intruding ~10%).
- Pipe line deviations at 8.46m, 13.60m, and 17.71m.
- Survey abandoned at 28.15m.
- Likely Cause: Tree or shrub roots penetrating aged concrete joints.
- Chalet Numbers: FHRA LAND
SECTION 3: SW1-OE3
https://fhra-media.s3.eu-west-1.amazonaws.com/SW1-OE3.mp4
- Issue:
- Fully surveyed.
- No defects identified.
- Chalet Number: FHRA Land but ends at front of 41 lawn
SECTION 4: SW1-SW2
- Issue:
-
Major structural failures:
- Displaced joints at 11.67m and 12.48m. CAR PARK BETWEEN 40/41? (One section of pipe) Drain at 17.21M
- Soil visible at both locations — risk of voiding and collapse.
- Broken pipe at 29.75m and again at 32.53m. NUMBER 39?
https://fhra-media.s3.eu-west-1.amazonaws.com/SW1-SW2.mp4
- Deformation at 10–30% cross-section loss.
-
Survey abandoned at 32.53m.
- Drains: SD2 (40)
- Chalet Number: FHRA Land + 39